THE ELMED ESU 120 M/M DIGITAL
ELECTROSURGICAL UNIT
The ELMED ESU 120 M/M DIGITAL with SMART-O-MATIC is specifically designed for otolaryngology procedures including general surgery applications, monopolar and bipolar, bipolar submucosal turbinate surgery, the radiofrequency treatment of theuvula , uvulopalatoplasty and tongue base reduction, and the radiofrequency treatment of obstructive tonsillar hypertrophy.
The ELMED ESU 120 M/M DIGITAL with SMART-O-MATIC was developed in collaboration with the most prominent surgeons. It provides the state-of-the art technology, reliability, and safety, at an affordable price.

List No. 5797 ELMED ESU 120 M/M DIGITAL, Electrosurgical Unit with SMART-O-MATIC circuit, select accessories as required
REQUIRED WORKING SYSTEM ACCESSORIES
List NO. 5707 Single pedal footswitch with 5-pin connector Return Electrode Accessories - Disposable List No. 5390 Patient plate, disposable, 7 1/2" x 6", 100 pcs. List No. 5395 Patient plate, disposable, self-adhesive, 6 1/4" x 5 1/4", 25 pcs. List No. 5702 Return cable for disposable patient plates and ELMED ESU's (reusable) Return Electrode Accessories - Non-Disposable List No. 5047 Patient plate, metal, for upper arm List No. 5044 Rubber strap, 20" long List No. 5701 Return cable for metal patient plate and ELMED ESU
OPTIONAL ACCESSORIES
List No. 4755 Equipment trolley with one drawer
THE ELMED ESU 120 M/M DIGITAL WITH SMART-O-MATIC FEATURES:
THREE DISTINCTIVE RADIO FREQUENCY OUTPUT MODES WITH AUTOMATIC OUTPUT COMPENSATION IN ALL MODES Mode I Pure cutting power by means of non-modulated RF-current and blended (Macro Output) power by modulated RF-current for cutting and coagulation Mode II Timed by the automatic timing circuit, low power level up to 10 W radio (Micro Output frequency current at a low voltage that generates low tissue temperature RFTA) specifically for Radio Frequency Thermal Ablation (uvulopalatoplasty and tongue base reduction) Mode III Bipolar non-modulated current for general bipolar surgical procedures and bipolar submucosal turbinate surgery according to Dr. Dennis DIGITAL READOUT Each mode has an independent digital wattage readout, as does the timing circuit for Radio Frequency Thermal Ablation. SAFETY CIRCUIT Automatic sensing device cuts off the output if the indifferent patient circuit is defective, and gives visual and audible alarm. Reusable or disposable electrodes may be used. Optional Return Electrode Monitor (REM) may be installed at extra cost. The operation of the ELMED ESU 120 M/M DIGITAL with SMART-O-MATIC is extremely easy. The generator is activated by means of a single pedal footswitch. SMART-O-MATIC CIRCUIT Our automatic output compensation circuit provides the desired output for all electrodes or tissue conditions. The automatic range control requires no readjustment within the set range. AUTOMATIC TIMING CIRCUIT The automatic timing circuit is triggered by the footswitch. The time can be selected between 1-10 seconds and is shown on the digital display and it will cut off the current flow as the time has expired, or when the surgeon removes his/her foot from the footswitch. It is reactivated to the same preset specifications by depressing the footswitch.
TECHNICAL DATA OF THE UNIT
Operating Frequency: 500 KHz
Power Supply: 117 V/60 Hz, other power requirements upon request
RF Output: Mode Pure: 100 Watts at 300 Ohm load, Mode Blend 1: 100 Watts at 300 Ohm load, Mode Bipolar: 50 watts at 100 Ohm load
Micro Setting, Monopolar, RFTA: Up to 10 Watts, low voltage sinusoidal RF-current operating through a timing circuit between one and ten seconds, controlled by the footswitch.
DIMENSIONS: Height: 6" Length: 15 1/2" Depth:12 1/2"
WEIGHT: 14 lbs.